Demonstrating HydraTite & Preventing Future Sinkholes

Demonstrating HydraTite & Preventing Future Sinkholes

Market

Storm Sewer

Challenge

A township in northern Ohio found a small portion of a road that had sunk in. Pouring water through the sinkhole indicated which joints were the culprits as water entered through the separation. The sinkhole was patched, but a solution was needed that could address the underlying issue and prevent further infiltration without affecting the road above.

HydraTite seal being installed in a demo seal
A small patch of concrete in a road

Engineered Solution

The HydraTite Internal Pipe Joint Seal, a trenchless solution, was selected to rehabilitate the failing joints.

Scope

The gold installation package was selected by the township. With this option, the client is provided with the materials and oversight from a HydraTech Field technician. HydraTech gave a demonstration on a portion of pipe in a department building and then followed the township personnel out to the jobsite to oversee the installation of two seals. Water was pumped to make installation easier and a patch of concrete was added at the invert of both joints, creating a uniform surface for proper installation. Then the EPDM seal was lightly lubricated and placed over the joint. The retaining bands were then expanded and locked into place. The installation only took two hours.

Concrete being applied to the invert of a pipe near a joint
A pair of loosely positioned retaining band laying otop the rubber seal
Lubricant being applied to the ribs of a HydraTite seal
HydraTite being installed by technicians tightening bolts
Lubricant being applied to the ribs of a HydraTite seal
Concrete being applied to the invert of a pipe near a joint
A pair of loosely positioned retaining band laying otop the rubber seal
HydraTite being installed by technicians tightening bolts

Solution

HydraTite will help prevent the future formation of additional sinkholes by eliminating the infiltration at a fraction of the cost and time that replacement would require.

HydraTite installed over a joint