PROVEN EXPERIENCE

WITH MEASURABLE RESULTS

CASE STUDY

Product Logo, 'HydraWrap, Structural Composite Repair System'

Restoring Integrity to 10-Inch Cast Iron Pipe

HydraWrap® (Fiber Reinforced Polymer)

Market
Sanitation

Challenge
A power generation facility in Kansas identified structural concerns on two 10-inch-diameter cast-iron cooling water supply pipes. The pipes, located just before isolation valves and adjacent to a concrete bulkhead, exhibited deterioration along critical sections. Conventional replacement would have required prolonged outages, significant excavation, and high cost—none of which were feasible for the facility’s operations.

Engineered Solution
HydraTech recommended HydraWrap®, a fiber-reinforced polymer (FRP) composite system designed for structural rehabilitation. For an additional layer of protection and long-term durability, a topcoat was also specified.

Scope
HydraTech supplied the HydraWrap materials and supervised the installation onsite, ensuring proper mixing, wet-out, and application procedures. First, the cast iron substrate’s surface was cleaned in accordance with SSPC SP-2/SP-3 standards. Once both locations had their surface prepared, primer epoxy was mixed and applied to the substrate. Next, the carbon fiber was saturated with wet-out resin, and the pipe was circumferentially wrapped. Eight inches were covered on the top of the pipe and four inches on its bottom, covering the bulkhead to the valve. Four complete circumferential wraps with 2-inch overlap ensured even stress distribution and full structural reinforcement. The installation was completed in a single day, minimizing downtime and disruption to plant operations.

Three image, posts that have become degraded by the elements, a post where a portion of the base has rotted away, a row of post that have had a portion of their base reinforced with HydraWrap

Solution
The HydraWrap® system successfully reinforced the two deteriorating cooling water pipes, restoring their structural integrity without the need for costly replacement. The HydraWrap system will protect this section of pipe from corrosion despite the high-moisture environment. The client received a structurally sound, corrosion-resistant solution that extended the service life of the pipes, safeguarded plant reliability, and demonstrated the value of trenchless composite repair technologies in critical infrastructure.

Three posts that have been damaged by weathering
New concrete poured around the base of a pavilion post. A lower portion of the post has been reinforced with HydraWrap
A pavilion whose posts have been reinforced with HydraWrap
New concrete poured around the base of a pavilion post. A lower portion of the post has been reinforced with HydraWrap
Three posts that have been damaged by weathering
Three posts that have been damaged by weathering
Three posts that have been damaged by weathering
Three posts that have been damaged by weathering
Three posts that have been damaged by weathering

Magnifying glass logo Explore HydraWrap

More information logo, negative plus sign More Products

Arrow bending back on itself to represent going back Case Studies

Magnifying glass logo
Explore HydraWrap

More information logo, negative plus sign
More Products

Arrow bending back on itself to represent going back
Case Studies

Magnifying glass logo
Explore HydraWrap

More information logo, negative plus sign
More Products

Arrow bending back on itself to represent going back
Case Studies

power plant pipeline repair

OUR PRODUCTS

Trenchless Repairs Custom Made

industrial pipe resotration

OUR INDUSTRIES

From Power to Water We Have It Covered

marine pipe sealing

OUR RESOURCES

Technical Data Sheets and Product Literature